← Admin VFD CONFIGURATION
CHANNEL & PROFILE
Channel
Profile
SLAVE ADDRESSES
VFD Description Slave Address
Main Blower 15 hp centrifugal — air mover into heat exchanger
Fire Blower 1.5 hp fire fan — controls heat from dome
Extractor Blower 1.5 hp extractor — vents damp air externally
Ambient Blower 5 hp ambient fan — introduces fresh air
STARTUP RAMP — MAIN BLOWER
Lengthening the drive ramp (P0-17 / P0-18) reduces inrush current and DC-bus sag that causes F-09 undervoltage on the 15 hp Main Blower. When enabled, these parameters are written to the drive on PLC startup (RAM only — reversible by disabling and power-cycling). Fire Blower is not affected (slow decel would delay fault stops).
Write ramp on startup
P0-17 acceleration time s
P0-18 deceleration time s
P0-19 time unit 0.1 s (fixed when writing on startup)
UNDERVOLTAGE DIAGNOSTICS
Bus voltage warn threshold V
Logs a warning when DC bus voltage drops below this value during polling. Set just above the drive undervoltage threshold (d5-06, default 350 V). Set to 0 to disable.
An unhandled error has occurred. Reload X